5 - 62 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
Item Setting details 
Setting value
1  
0: Auto tuning selected for use 
of interpolation axis control, 
etc. in position  
1: Auto tuning for ordinary 
operation. 
2: Invalid (No auto tuning) 
 
Pr.108
 
Auto tuning  Used to select the auto tuning. 
0: Interpolation mode 
1: Auto tuning mode 1 
2: Manual mode 2 
3: Auto tuning mode 2 
4: Manual mode 1 
 
 
 
 
 
1: Normal mode   
2: Normal mode   
3: Normal mode   
4: Normal mode   
5: Normal mode   
8: Large friction mode   
9: Large friction mode   
A: Large friction mode   
B: Large friction mode   
C: Large friction mode   
1: Low response (15Hz) 
 
2: Low response (20Hz)   
3: Low response (25Hz)   
4: Low response (30Hz)   
5: Low response (35Hz)   
6: Low response (45Hz)   
7: Low response (55Hz)   
8: Middle response (70Hz)   
9: High response (85Hz)   
A: High response (105Hz)   
B: High response (130Hz)   
C: High response (160Hz)   
D: High response (200Hz)   
E: High response (240Hz)   
Servo basic parameters 
Pr.109
 
Servo response 
Used to set the response of auto tuning. 
(When 
Pr.108
 
Auto tuning is valid) 
Optimum response can be selected according to the 
rigidity of the machine. As machine rigidity is higher, 
faster response can be set to improve tracking 
performance in response to a command and to 
reduce setting time. 
F: High response (300Hz)