1 SAFETY
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
38
Pub. No. K29001-00320 Revision: 1
â–  Cooling Operation
â–  Stopping
Check exhaust pipes and pipe joints
for exhaust gas leaks.
* Otherwise, it may cause carbon monoxide
intoxication and lead to death at the worst.
* If an exhaust leak is found, contact your SME
dealer.
If an abnormal engine oil pressure
drop is observed, stop the engine
immediately, and check the engine oil
system to locate the cause.
* Sustained use of the engine without any
remedy could cause seizure of the bearings and
lead to serious damage to the devices.
* If the cause of problem cannot be located,
contact your SME dealer.
If a belt breaks, stop the engine
immediately and replace the belt.
* Sustained use of the engine without any
remedy could cause defective battery charge
and cooling fault, and result in serious engine
problems.
Keep the intake air temperature at
the specified level.
* If the intake air temperature is higher than the
specified level, the engine stopping device may
work due to the increased exhaust temperature
and stop the engine suddenly.
* The thermal load could increase excessively
and will cause piston scuffing.
* If the intake air temperature cannot be kept at
the specified level, reconsider the operating
conditions and operating time.
Keep the engine oil and coolant
temperatures at the specified level.
* If the engine oil or coolant temperatures is
increased, the engine stopping device may
work due to the increased exhaust temperature
and stop the engine suddenly.
Except in a time of emergency,
operate the engine at low idle for 5 to
6 minutes to cool down before
stopping the engine.
* If the engine is stopped without cooling down,
the devices could be damaged.
Do not stop the engine suddenly at
high speed.
* It could cause damage to the devices due to
degradation of the damper or stopped
circulation of the engine oil to the turbocharger.
Do not restart the engine immediately
after an abnormal stop.
* Investigate the cause of abnormality, correct
the defect, then restart the engine.
Do not race the engine immediately
before shutting it down.
* Otherwise, the devices could be damaged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi S16R Series and is the answer not in the manual?

Mitsubishi S16R Series Specifications

General IconGeneral
BrandMitsubishi
ModelS16R Series
CategoryEngine
LanguageEnglish

Related product manuals