RWA000Z251
Model SRK71ZM-S
to which the information relates to: If function includes heatin
season the
Indoor unit model name SRK71ZM-S information relates to. Indicated values should relate to one
Outdoor unit model name SRC71ZM-S heating season at a time. Include at least the heating season 'Average'.
Function(indicate if present) Average(mandatory) Yes
cooling Yes Warmer(if designated) No
heating Yes Colder(if designated) No
Item
s
n load Seasonal efficienc
class
cooling Pdesignc 7.10 kW cooling SEER 6.06 A+
heating / Average Pdesignh 7.60 kW heating / Average SCOP/A 4.03 A+
heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -
heating / Colder Pdesignh - kW heating / Colder SCOP/C - -
unit
Declared capacit
at outdoor temperature Tdesi
at outdoor temperature Tdesi
nh
heating / Average (-10℃) Pdh 6.49 kW heating / Average (-10 ℃) elbu 1.11 kW
heating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kW
heating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW
Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ and
outdoor temperature T
Tj=35℃ Pdc 7.10 kW Tj=35℃ EERd 3.29 -
Tj=30℃ Pdc 5.23 kW Tj=30℃ EERd 5.00 -
Tj=25℃ Pdc 3.36 kW Tj=25℃ EERd 8.70 -
Tj=20℃ Pdc 4.27 kW Tj=20℃ EERd 9.00 -
Declared capacit
e season, at indoor Declared coefficient of performance / Avera
e season, at indoor
temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh 6.72 kW Tj=-7℃ COPd 2.30 -
Tj=2℃ Pdh 4.09 kW Tj=2℃ COPd 3.93 -
Tj=7℃ Pdh 2.63 kW Tj=7℃ COPd 5.80 -
Tj=12℃ Pdh 2.56 kW Tj=12℃ COPd 7.10 -
Tj=bivalent temperature Pdh 6.72 kW Tj=bivalent temperature COPd 2.30 -
Tj=operating limit Pdh 6.10 kW Tj=operating limit COPd 2.10 -
Declared capacit
/ Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoor
temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Tj=2℃ Pdh - kW Tj=2℃ COPd - -
Tj=7℃ Pdh - kW Tj=7℃ COPd - -
Tj=12℃ Pdh - kW Tj=12℃ COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Declared capacit
/ Colder season, at indoor Declared coefficient of performance / Colder season, at indoor
temperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature Tj
Tj=-7℃ Pdh - kW Tj=-7℃ COPd - -
Tj=2℃ Pdh - kW Tj=2℃ COPd - -
Tj=7℃ Pdh - kW Tj=7℃ COPd - -
Tj=12℃ Pdh - kW Tj=12℃ COPd - -
Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -
Tj=operating limit Pdh - kW Tj=operating limit COPd - -
Tj=-15℃
Pdh - kW
Tj=-15℃
COPd - -
Bivalent temperature
Operatin
limit temperature
heating / Average Tbiv -7 ℃ heating / Average Tol -15 ℃
heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃
heating / Colder Tbiv - ℃ heating / Colder Tol - ℃
C
radation coefficient
cooling Cdc 0.25 - heating Cdh 0.25 -
Electric power input in power modes other than 'active mode'
Annual electricit
consumption
off mode Poff 10 W cooling Qce 411 kWh/a
standby mode Psb 10 W heating / Average Qhe 2643 kWh/a
thermostat-off mode Pto 56 W heating / Warmer Qhe - kWh/a
crankcase heater mode Pck 0 W heating / colder Qhe - kWh/a
Capacit
indicate one of three options
Other items
Sound power level(indoor) Lwa 60 dB(A)
Sound power level(outdoor) Lwa 66 dB(A)
fixed No Global warming potential GWP 1975 kgCO2eq.
staged No Rated air flow(indoor) - 1110 m3/h
variable Yes Rated air flow(outdoor) - 3300 m3/h
Contact details for obtainin
Name and address of the manufacturer or of its authorised representative.
more information
Mitsubishi Heav
Industries Air-Conditionin
Europe, Ltd.
7 Roundwood Avenue, Stockle
e, Middlesex, UB11 1AX,
United Kin