MK-101 w/JCS Stand Revision 04/05, Effective Date August 19, 2005
Page 19
SETUP, ADJUSTMENT and OPERATION
3. Water Pump Setup for Operation:
The Water Pump can be setup for operation in two ways, External Water Source or Re-circulation.
NOTE: If using a dry blade for operation, DO NOT connect the water pump.
I. External Water Source:
This is the preferred method of cooling.
II. Re-circulation:
NOTE: When using the re-circulation method, the water should be changed often for longer pump life.
(A)
Remove the Drain plug
(B)
Place the Water Pump
In an external container
(C)
Fill the external container until
water completely covers the
Water Pump suction
(A)
Ensure the Drain Plug is
Installed in the Water Basin
(B)
Place the Water Pump in the back
of the Water Basin.
(C)
Fill the Water Basin until water
completely covers the
Water Pump suction
Cover Pump
Suction
Drain Plug Water Pump
In containe
r
External
Containe
r
Drain Plug
Installed
Water
Pump
Cover Pump
Suction
(A)
Place Water Pump in Water Pan
(B)
Place Water Pump Clamp as shown
(C)
Secure Clamp with ¼-20
wingscrews and nuts.

Other manuals for MK MK-101