Technical data MCG15
18
11 Technical data
I
Test/certificates:
The coolant circuit contains R134a.
This product contains fluorinated greenhouse gases.
The cooling unit is hermetically sealed.
MCG15
Connection voltage: 12/24 Vg
100 to 240 Vw
Rated current: 12 Vg: 4 A
24 Vg: 2 A
100 Vw: 0.85 A
240 Vw: 0.4 A
Cooling capacity: –18 °C to +20 °C
Total volume: 15 l
Climate class: N
Ambient temperature: +16 °C to +32 °C
Refrigerant volume: 35 g
CO
2
equivalent: 0.05 t
Global warming potential (GWP): 1430
Dimensions (L x W x H): 587 x 344 x 261 mm
Weight: 9.5 kg
NOTE
If the ambient temperature is above +32 °C, the minimum tempera-
ture cannot be attained.