OPERATING MANUAL
COMP-U-DIFF
MODEL 10-329
386 Main Street Redwood City, CA 94063
Ph (650) 365-3111 FAX (650) 365-6111
WWW.MODULUSDATASYSTEMS.COM
Question and Answer IconNeed help?

Do you have a question about the Modulus COMP-U-DIFF 10-329 and is the answer not in the manual?

Summary

General Information

Key Features

Details the key characteristics and capabilities of the COMP-U-DIFF instrument.

Physical Layout

Function Keys Overview

Explains the location and operation of the primary function keys on the device.

Counting and Quantifying Procedures

Describes the usage of function keys for cell counting and result quantification.

Data Entry and Quick Demo

Data Entry Keys Functionality

Details the functions of the data entry keys for specimen and numeric input.

COMP-U-DIFF Quick Demo Guide

A step-by-step guide to demonstrate basic COMP-U-DIFF operations for new users.

Device Operation Guide

Power On and Initial Setup

Covers connecting the power and the initial screen display upon startup.

Specimen ID and Date Entry

Instructions for entering specimen identification and collection dates.

Differential Counts Entry

Explains the procedure for inputting differential cell counts using the keypad.

Differential Counts and Cell Categories

Differential Counts Continued

Further instructions on entering differential cell counts and related operations.

Additional Cell Categories Setup

Information on redefining channels for expanded cell counting capabilities.

Count Conversion and Correction

Convert Counts to Percentage

How to display cell counts as a percentage of the total.

Subtracting Counts (Decrement)

Procedure for correcting counts by subtracting entries.

Lockout and Non-Total Key Features

Explains the lockout feature and the function of the non-total key.

Morphology and Comment Entry

Morphology Selection Process

Guides on entering morphology selections using the device's interface.

General Comments Entry

Instructions for entering up to four general comments for each specimen.

Operating Modes Explained

Store Mode Operation

Allows gathering and storing specimen data in batch memory.

Recall Mode Operation

Enables retrieval and review of stored specimen data.

Batch Mode Operations

Covers sending all stored reports and related operations.

Clearing Data from Memory

Clearing Selective Data

How to erase individual specimen records from memory.

Clearing All Records

Procedure for erasing the entire batch memory.

Data Transmission Procedures

Sending Single Report On-Line

Transmitting a report directly to the host computer while in STORE mode.

Sending Single Report From Memory

Transmitting stored reports to the computer or printer.

Sending All Stored Reports

Bi-directional Operation Time-Out

Explains the time-out feature during bi-directional communication.

Hemogram Data Recall

Hemogram Data Display and Scrolling

Describes how hemogram data is displayed and navigated on the COMP-U-DIFF screen.

Programming Considerations

Data Format Specifications

Specifies the required data format for communication with the LIS computer.

Computer Dialog ASCII Characters

Lists the ASCII characters used in the computer interface dialog.

Instrument Installation Guide

Jumper Plug Settings Overview

Details the user-selectable jumper settings for various options.

Factory Settings Assessment

Explains how to view and assess the internal factory settings of the unit.

User Changeable Settings

Detailed Jumper Settings

Provides in-depth explanations for each jumper setting and its function.

Computer Interface and Port Details

RTS;CTS Jumper Configuration

Describes the function of the RTS/CTS jumper for operation modes.

Printer and Computer Port Layout

Details the physical layout and connection types for printer and computer ports.

Helpful Operational Hints

Standalone Counter Operation

Instructions for using the COMP-U-DIFF as a standalone counter.

Key Assignment Overlay Usage

Information on using and ordering key assignment overlays for customization.

Absolute Counts Calculation

How to express cell counts in terms of absolute WBC.

User-Defined Comment Dictionary

Guidance on creating and using user-defined comments.

Exhibit 1: Computer Data Format

Data Format Parameter Definitions

Lists character positions and their corresponding parameter names in the data format.

Exhibit 2: User Comments Table

User-Defined Comments Guide

Provides suggestions for user-defined comments and their 3-digit codes.

Exhibit 3: Ticket Printer Comment Codes

Ticket Printer Comment Codes

Lists comment codes for ticket printer output, including quantifiers.

Warranty Policy Information

US Repair Service Instructions

Instructions for obtaining repair service within the USA.

Foreign Repair Service Instructions

Guidance on receiving repair service for instruments located internationally.

Modulus COMP-U-DIFF 10-329 Specifications

General IconGeneral
BrandModulus
ModelCOMP-U-DIFF 10-329
CategoryCash Counter
LanguageEnglish