Standard form for user defined
parameter settings
17
PNU Meaning Value range Def. Setpoint
F001 Frequency setpoint value 0.00 to 400 Hz 0.0
F002 Acceleration time 1 0.01 to 3600 s 30.0
F202 Acceleration time 1 (second parameter set) 0.01 to 3600 s 30.0
F003 Deceleration time 1 0.01 to 3600 s 30.0
F203 Deceleration time 1 (second parameter set) 0.01 to 3600 s 30.0
F004 Direction of rotation 00: Clockwise operation
01: Anticlockwise operation
00
PNU Meaning Value range Def. Setpoint
H003 Motor rating 0.2 to 160 kW Depending
on inverter
model
H203 Motor rating (second parameter set) 0.2 to 160 kW
H004 Number of motor poles 2, 4, 6, 8 4
H204 Number of motor poles
(second parameter set)
2, 4, 6, 8 4
H006 Motor stabilization constant 0 to 255 100
H206 Motor stabilization constant
(second parameter set)
0 to 255 100
PNU Meaning Value range Def. Setpoint
U001 User-defined parameters PNU A001 to H206 no
U002 no
U003 no
U004 no
U005 no
U006 no
U007 no
U008 no
U009 no
U010 no
U011 no
U012 no