-75-
Revision 5/F3528
B.1 110 VOLT G32 MODELS, USA / CANADA
Up to serial number 203926
Make White Rodgers
Type 50D20-150 or 50D20-152
Case Colour White
Voltage 24Vac (18-30Vac), 50Hz
Ignition Trial Period 7 Seconds
Pre-purge 0 seconds
Ignition Retries 2 (60 second purge)
Re-ignition Attempts 4
Spark Rate 60 Hz
Spark Voltage 25 kV
Lockout Indicator At top of casing (internal)
Flashing light confirms lockout condition.
If light is on steady, electrical fault exists.
Minimum Flame Current 1 µA
From serial number 203927
Make Fenwal
Type 2460D-506-023
Case Colour Grey
Voltage 24Vac (18-28Vac)
Ignition Trial Period 7 Seconds
Pre-purge 0 seconds (3.5 second delay on initial start)
Ignition Retries 2 (30 second purge)
Re-ignition Attempts 2
Spark Rate 60 Hz
Spark Voltage 25 kV
Lockout Indicator At rear of casing
2 flashes indicates flame error.
3 flashes confirms lockout condition.
Minimum Flame Current 0.7 µA
APPENDIX B. IGNITION BOX SPECIFICATIONS