EasyManua.ls Logo

Mongoose M80i - Remote Code Learning

Mongoose M80i
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NSW SIREN TIMING (default = OFF)
It is a mandatory requirement in New South Wales, Australia, for vehicle alarm systems to sound the
siren for one cycle of 30 seconds only before it is re-set manually by remote control. With this
feature turned on, the indicators will flash for any subsequent trigger.
PERIMETER NITE-LITE (default = OFF)
Upon disarming, the indicators will stay permanently lit for 15 seconds to provide perimeter
illumination. Ask the installer to verify that the power consumption of all the indicators is within the
tolerance of this product- maximum 8 amps per side.
SIREN/HORN OUTPUT (default = siren)
This programme allows for connection to a vehicle horn. The output is then pulsed.
DOOR DIAGNOSTICS (default = ON)
This is factory set to ON. If for example a door is left open when arming, the siren chirps once for
ARM then after a short pause, chirps a second time to signify a circuit is open. Some vehicles which
have ‘dome light delay’ may give a false signal this feature should then be programmed OFF.
TURBO TIMER RUN TIME (default = 2 minutes)
This allows an engine to remain running from its built-in timer. The programme allows for an engine
running time of 1, 2, 3, 4 or 5 minutes. This programme only adjusts the engine running time, see
page 7 for on/off function
COURIER MODE / TURBO INTERFACE FUNCTION (default = OFF)
This allows the alarm to be armed with the engine running by an aftermarket turbo timer or to allow
for applications such as ‘courier run on’.
An alarm trigger will stop the engine immediately.
14

Related product manuals