Eco Convection Ovens | 4/5/7/10-Tray | Steam Installation and Operation Manual
84
MONO FG1BX-UK-MAN-0100 | Rev. A23 (March 2023)
Installation (condenser unit)
1. Ensure that all power is disconnected and the oven is cool.
2. Before fitting the main condenser assembly, insert blanking plug (A) into the lower hole that will not be
required for the type of oven being used.
3. Connect tube (B) to the spigot and retain with worm-drive clip (C).
4. Place condenser in position, ensuring that the tube (B) passes through the hole in the top of the oven and
worm drive clip (D), then over spigot of the damper assembly on the oven.
5. Tighten worm-drive clip (D).
6. Fasten the condenser unit to the top of the oven with M6 x 12 mm long hex head screws and washers in
four positions. (If holes have been drilled, nuts will have to be also used).
7. Connect wiring, depending on whether the oven is a 4-tray or 10-trays version, as shown in the
corresponding Electricals manual.
8. Connect drain hose to a suitable drain.
9. Attach a water tap bracket to the base frame, as shown, and fasten the water hose to a water supply.
(A tee pipe must be used on double ovens).
NOTE
If fixing holes are not present on the top sheet of the oven, they should be marked and drilled at this stage.
Position condenser correctly and mark hole positions (centre of each slot). Remove condenser and drill holes
of 6.5 mm diameter at four positions.