SOLAR CONTROLLERS
OPERATORS MANUAL
P
RO
S
TARTAR -12
PROSTAR VERSIONS INCLUDED IN THIS MANUAL
PS-15 PS-30 PS-15M-48V
Rated Solar Current 15A 30A 15A
Rated Load Current 15A 30A 15A
System Voltage 12/24V 12/24V 48V
Digital Meter Option yes yes standard
Positive Ground Option no yes yes
PROSTAR VERSIONS INCLUDED IN THIS MANUAL
1098 Washington Crossing Road
Washington Crossing, PA 18977 USA
phone: 215 321 4457
fax: 215 321 4458
email: info@morningstarcorp.com
Question and Answer IconNeed help?

Do you have a question about the Morningstar ProStar-15 and is the answer not in the manual?

Summary

General Information

Important Safety Information

Quick Start Instructions

LED Indicators

Digital Meter & Manual Disconnect

Digital Meter

Precision 3-digit display of battery voltage, solar, and load current.

Manual Disconnect

Button to disconnect Load or both Load and Solar.

Display Disconnects & Protections

Protection functions and disconnect conditions displayed on the meter.

Self-Diagnostics (Self-Test)

Initiates automatic self-diagnostics to test for faults.

Installation Instructions

General Installation Notes

Key considerations for proper installation and performance.

Installation Steps

A detailed, step-by-step procedure for installing the ProStar.

Operation

Operators Tasks

Outlines the primary manual tasks performed by the system operator.

Operations & Functions

Protections

Inspection & Maintenance

Special Features

Remote Temperature Probe

Optional probe for remote temperature measurement and compensation.

Telecom Noise Jumper

A jumper to cut to eliminate noise for telecom equipment.

Battery Charging Information

ProStar Charging Method

Explains the 4 stages of ProStar battery charging.

Select Battery Type

Guide to selecting the correct battery type for charging algorithms.

ProStar Charging Features

Lists additional features enhancing battery life and performance.

Testing and Troubleshooting

Self-Diagnostics

Instructions for performing a self-test on the ProStar controller.

Technical Support

Information on obtaining additional technical support and resources.

Testing with a Power Supply

Procedure for testing the ProStar using an external power supply.

Troubleshooting

Battery Is Not Charging

Troubleshooting steps for when the battery fails to charge.

Battery Voltage Is Too High

Diagnosing and resolving issues related to excessively high battery voltage.

Load Is Not Operating Properly

Steps to troubleshoot and resolve load operation problems.

Technical Specifications

Electrical

Detailed electrical specifications for the ProStar controller.

Battery Setpoints (@ 25°C)

Specific voltage setpoints for different battery types at 25°C.

Battery Charging

Information on charge algorithms and temperature compensation settings.

Mechanical

Physical dimensions, weight, and wire terminal specifications.

Environmental

Operating and storage conditions including temperature and humidity.

Meter Display

Specifications related to the optional LCD meter display.

Battery Status LEDs

Voltage parameters associated with the battery status LED indications.

Morningstar ProStar-15 Specifications

General IconGeneral
BrandMorningstar
ModelProStar-15
CategoryController
LanguageEnglish