12
DK ENG
In the US, oor protection must be constructed of a non-combustible material and installed
to extend beneath the heater and 16’’ to the front and 8’’ to the sides of the fuel loading
door and ash removal openings. In Canada, oor protection must be constructed of a non-
combustible material and installed to extend beneath the heater and 450 mm.(16’’) to any
side with a door and 200 mm.(8’’) beyond the appliance on the other sides.
Distance to furniture
The recommended minimum distance from stove to furniture is 30 inches. Note that some
furniture is more easily aected by heat and may need to be moved to a greater distance.
This is your responsibility.
In addition other combustible materials, away from the stove. In general, a distance of 30
inches must be maintained between the stove and moveable combustible item such as dry-
ing clothes, newspapers, rewood etc.
DO NOT INSTALL IN A MOBILE HOME
Note:
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof
cover.
Fresh Air Inlet
Unless there is deemed to be sucient ambient leakage of air into the room via doorways, windows
and the like, a dedicated fresh air inlet will be needed. This inlet should have 2 square inches (1250
square mm) of free air space. This is particularly important where the room is well sealed, or where
an extractor hood or ventilation system disturbs the natural air pressure. Such an inlet should not
be on a wall that is usually subject to negative pressure from normal wind pattern. Avoid placing the
inlet directly across the room from the stove, thus causing a cold air draft.
Floor protection requirements Non-combustible materials be-
neath stove
USA Canada
A. Extending distance, back
B. Extending distance, right side
C. Extending distance, left side
D. Extending distance, front
-
6”
6”
16”
200 mm
200 mm
200 mm
450 mm

Other manuals for Morso 2B Classic