1.5 Positioning the stove
Distance to walls and lintel
When the stove is positioned near combustible materials, observe all current local and national
building regulations with regards to clearances. Whatever regulations apply to your area, do
not in any case install the stove within 8 inches of combustible materials around the sides or
16 inches above the top of the stove (fireplace installations require greater clearances above
the stove - see below in the clearance chart). These distances may need to be increased if the
materials are sensitive to heat. Note also that wall paper and other decorative materials may
become detached with the effects of heat and care should be taken to ensure that they do not
fall towards the stove in such an event.
When the stove is positioned near non-combustible materials, a gap of 4 inches or more is
recommended for cleaning purposes and to ensure that heat circulates around the stove and
out into the room.
If using rear exit, the floor protection must extend beneath the chimney connector and 2-in
beyond each side.
CLEARANCES IN ( ) IN MM FOR CANADA FOR NON-
COMBUSTIBLE FLOOR PROTECTOR
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
SINGLEWALL CONNECTOR
USA CANADA
A.
B.
C.
D.
E.
F.
G.
H.
10’’
6’’
6’’
17’’
11’’
13’’
43,5’’
84’’
254 mm.
152 mm.
152 mm.
432 mm.
279 mm.
330 mm.
1105 mm.
2134 mm.
SIDEWALL TO UNIT
BACKWALL TO UNIT
CORNERWALL TO UNIT
SIDEWALL TO CONNECTOR
BACKWALL TO CONNECTOR
CORNERWALL TO CONNECTOR
UNIT TO CEILING
FLOOR TO CEILING
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
DOUBLEWALL CONNECTOR
USA CANADA
A.
B.
C.
D.
E.
F.
G.
H.
10’’
2’’
3,5’’
17’’
7’’
10,5’’
43,5’’
84’’
254 mm.
51 mm.
89 mm.
432 mm.
178 mm.
267 mm.
1105 mm.
2134 mm.
SIDEWALL TO UNIT
BACKWALL TO UNIT
CORNERWALL TO UNIT
SIDEWALL TO CONNECTOR
BACKWALL TO CONNECTOR
CORNERWALL TO CONNECTOR
UNIT TO CEILING
FLOOR TO CEILING
CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION
REAR VENT OUT BACK WALL
SINGLEWALL CONNECTOR
USA CANADA
A.
B.
C.
D.
E.
F.
G.
H.
9,5’’
6’’
-
17’’
-
-
-
-
241 mm.
152 mm.
-
432 mm.
-
-
-
SIDEWALL TO UNIT
BACKWALL TO UNIT
CORNERWALL TO UNI
SIDEWALL TO CONNECTOR
BACKWALL TO CONNECTOR
CORNERWALL TO CONNECTOR
UNIT TO CEILING
FLOOR TO CEILING
CLEARANCE REQUIREMENTS ALCOVE INSTALLATION
SINGLEWALL CONNECTOR
USA CANADA
A.
B.
C.
D.
E.
F.
G.
H.
10,5’’
8’’
-
18’’
13’’
-
36,5’
77’’
267 mm.
203 mm.
-
457 mm.
330 mm.
-
927 mm.
1956 mm.
SIDEWALL TO UNIT
BACKWALL TO UNIT
CORNERWALL TO UNI
SIDEWALL TO CONNECTOR
BACKWALL TO CONNECTOR
CORNERWALL TO CONNECTOR
UNIT TO CEILING
FLOOR TO CEILING
CLEARANCE REQUIREMENTS ALCOVE INSTALLATION
DOUBLEWALL CONNECTOR
USA CANADA
A.
B.
C.
D.
E.
F.
G.
H.
10,5’’
5’’
-
18’
10’’
-
36,5’’
77’’
267 mm.
127 mm.
-
457 mm.
254 mm.
-
927 mm.
1956 mm.
SIDEWALL TO UNIT
BACKWALL TO UNIT
CORNERWALL TO UNI
SIDEWALL TO CONNECTOR
BACKWALL TO CONNECTOR
CORNERWALL TO CONNECTOR
UNIT TO CEILING
FLOOR TO CEILING

Related product manuals