July 16, 2004 6881094C28-D
6-4 Radio Alignment Procedures: Radio Information
6.4 Radio Information
Figure 6-4 shows a typical Radio Information screen. This screen is informational only and cannot be
directly changed.
Figure 6-4. Radio Information Screen
6.5 Reference Oscillator Alignment
Adjustment of the reference oscillator is critical for proper radio operation. Improper adjustment will
result not only in poor operation, but also in a misaligned radio that will interfere with other users
operating on adjacent channels. For this reason, the reference oscillator should be checked every
time the radio is serviced, or once a year, whichever comes first. The frequency counter used for this
procedure must have a stability of 0.1 ppm (or better).
NOTE: Reference oscillator alignment is required after replacing (or servicing) the transceiver board.
This test can be done with either the R-2670 Communication Analyzer or the 8901_ Modulation
Analyzer.
• Initial setup using the R-2670 Communication Analyzer:
- RF Control: MONITOR
-B/W: WB
- Freq: CPS frequency under test
- Attenuation: 20dB
- Mon RF in: RF I/O
- Meter: RF Display
- Mode: STD
- Input Level: uV or W
- Display: Bar Graphs
- Squelch: Mid-range or adjust as necessary
• Initial setup using the 8901_ Series Modulation Analyzer:
- Press the green Automatic Operation button on the analyzer.
-Press the FREQ key.