EasyManua.ls Logo

Motorola ASTRO XTS 5000 - Radio Information; Reference Oscillator Alignment; Figure 6-4. Radio Information Screen

Motorola ASTRO XTS 5000
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 16, 2004 6881094C28-D
6-4 Radio Alignment Procedures: Radio Information
6.4 Radio Information
Figure 6-4 shows a typical Radio Information screen. This screen is informational only and cannot be
directly changed.
Figure 6-4. Radio Information Screen
6.5 Reference Oscillator Alignment
Adjustment of the reference oscillator is critical for proper radio operation. Improper adjustment will
result not only in poor operation, but also in a misaligned radio that will interfere with other users
operating on adjacent channels. For this reason, the reference oscillator should be checked every
time the radio is serviced, or once a year, whichever comes first. The frequency counter used for this
procedure must have a stability of 0.1 ppm (or better).
NOTE: Reference oscillator alignment is required after replacing (or servicing) the transceiver board.
This test can be done with either the R-2670 Communication Analyzer or the 8901_ Modulation
Analyzer.
Initial setup using the R-2670 Communication Analyzer:
- RF Control: MONITOR
-B/W: WB
- Freq: CPS frequency under test
- Attenuation: 20dB
- Mon RF in: RF I/O
- Meter: RF Display
- Mode: STD
- Input Level: uV or W
- Display: Bar Graphs
- Squelch: Mid-range or adjust as necessary
Initial setup using the 8901_ Series Modulation Analyzer:
- Press the green Automatic Operation button on the analyzer.
-Press the FREQ key.