Chapter 4 Performance Checks
4.1 General
These radios meet published specifications through their manufacturing process by utilizing high-
accuracy laboratory-quality test equipment. The recommended field service equipment is as accurate
as the manufacturing equipment with few exceptions. This accuracy must be maintained in
compliance with the manufacturer’s recommended calibration schedule.
4.2 Power-Up Self Test
Applying power to the radio by using the on/off volume control, starts a self-test routine which checks
the RAM, EEPROM hardware and EEPROM checksum. Pressing and holding SB1 while turning on
the radio causes the self-test routine to check for the ROM checksum as well. If these checks are
successfully completed, the radio will generate the Self-Test Pass Tone. If the self-test is not
successful, a Self-Test Fail Tone is heard.
Figure 4-1. Radio Tuning Setup
Service Monitor or
Counter
Wattmeter
Audio Generator
Sinad Meter
AC Voltmeter
30 dB Pad
30 dB Pad
Battery
Eliminator
Power
Supply
Audio In
Tx
Rx
Receive
Transmit
RF Generator
BNC
RF Adaptor
5886564Z01
RIB
RLN4008
RIB Power Supply
RLN4460
Test B o x
Rx
Gnd
Data
Tx Data
Radio
Computer Interface
Cable
Program/
Test Cable
PMKN4004
RLN4510
Power Cable

Table of Contents

Other manuals for Motorola CP140