TEST SETUP & TESTING MTM700 Mobile Terminal / Basic Service Manual 5 - 3
Test Check List
The following table summarises the required test setups.
(Values for 380-430 MHz radio in brackets [  ])
Table 2    Test setup
No. Test Name Test Setup Radio Setup Test Conditions Limits
1. Base Station 
Registration
Control Channel For 800MHz radio:
851.0125MHz
[ For 400MHz radio:
421.0125MHz ]
For 800MHz radio: 
2040
[ For 400MHz radio: 
840 ]
Traffic Channel For 800MHz radio: 
2040 
[ For 400MHz radio: 
840 ]
Time Slot 3
Country Code 262
Network Code 75
Base Color 1
Location Area 224
Min Rx Level -120dBm
Max Tx Level 35dBm (3.2W)
Access 
Parameter
-53dBm
Mobile Power 35dBm (3.2W)
Burst Type Normal
2. Receiver RSSI RF Gen Level 4 Cells Info
RSSI
TRACE
-90dBm
3. Transmitter 
Tests
RF Gen Level  Range 1
Talk Group 1
-90dBm
Burst Power 33-37dBm
Timing Error <=0.25 Symbols
Frequency 
Error
-/+ 80Hz
Vector Error Max 10% RMS, 
Max 30% Peak,
Max 5% Residual
4. Call Processing 
Talk Back
1KHz Test Signal
Group Mode
Range 1
Talk Group 1
-90dBm
5. Call Processing 
Call to Mobile
Private Mode
Private Call
Private Mode
RF Gen Level 
Burst Power
-90dBm 33-37dBm
Timing Error <=0.25 Symbols