Table 17: Preparing New (Never Calibrated) IMPRES 2 or IMPRES
Lithium-Ion Batteries for Shipment - Calibration Required
Status Charger Display LED Indicator
Charger Powers On
IMPRES 2
CHARGER
Green for approximately one
second
Battery Detected
IMPRES 2
BATTERY
or
IMPRES
BATTERY
Battery requires Calibration, but
Calibration is disabled by Ship
Lithium:
Alternating Amber/
Green for four seconds
Battery Discharging
(Discharging to find 0%
Rated Capacity)
SHIP LI DISCHRG
Steady Amber
Rapid Charging (Charging
to selection)
SHIP LI CHARGE
xx% Rated Cap
Steady Red
Charge Complete
Ready to Ship
LI READY TO SHIP
xx% Rated Cap
Battery does not require
Calibration:
Steady Green
Battery requires Calibration:
Alternating Amber/
Green
Fault
Battery Faulted
No discharge current
Capacity too low to
complete charge
Warning:
NOT CHARGEABLE
REMOVE& REINSERT
or
CANNOT DISCHARGE
FOR LI SHIPMENT
or
SHIP INCOMPLETE
Low Capacity:yy%
Flashing Red
MN003555A01.book Page 29 Wednesday, February 14, 2018 2:40 PM