Charger Troubleshooting
Table 21: Charger Reprogramming Display Options
Charger Display Description
REPROGRAMMING
REMOVE BATTERIES
Remove batteries from the charger pockets before
reprogramming.
REPROGRAMMING
WAITING FOR DATA
All charger pockets are empty.
REPROGRAMMING
Progress yyy%
Reprogramming data is downloading. For chargers with a display
associated with each pocket, the percentage value is the
percentage of data successfully downloaded into the pocket
associated with the display. For chargers that have only one
display (Pocket 1), the percentage value is the percentage of data
successfully downloaded into all six pockets.
REPROGRAMMING
POCKET#xx FAILED
Reprogramming failed in the identified pocket. The identified
charger pocket will start normal operations using the previous
software.
IMPRES 2
CHARGER
Reprogramming data download is complete. The charging is
completing the Reprogramming process.
REPROGRAMMING
COMPLETE
The Reprogramming process completed successfully. The
charger will start normal operations using the newly downloaded
software.
Table 22: Troubleshooting
Problem What to do...
Charger powers
ON, but the LED
does not flash
Green.
Make sure that the power cord is securely plugged into the
charger and an appropriate AC power outlet, and that there is
power to the outlet.
Inspect fuses and replace as necessary.
Battery inserted, but
LED remains OFF
and display does
not identify battery.
If battery is inserted into any Pocket (except Pocket 1), and if
Power Saver is Enabled, then press the Menu button.
See Fault.
MN003555A01.book Page 47 Wednesday, February 14, 2018 2:40 PM