40)
Start signal OFF delay time
Number Unit Range Initial
P89
0 ~ 1000 0
Description
Customer lost the fastening OK output when operator release
start lever just before torque up, but clutch was activated by
inertia. Range
: 0 - 1,000
mS factory setting
:10
mS
41)
Error history
(
except the pattern error
)
42)
Others
(
Not changeable
)
Number Unit Range Initial
P160~167
Description
The total
8
latest errors except the pattern error is recorded
from P160 to P169.
P160
:
The last error P164
:
The last error
-4
th
P161
:
Before the last error P165
:
The last error
-5
th
P162
:
The last error
-2
nd P166
:
The last error
-6
th
P163
:
The last error
-3
rd P167
:
The last error
-7
th
No Name Range Initial Description
P82 Air Regulator
0-1 1 0:
No use
1:
Use
P100-139 Memory area of model data
P140-159 Memory area of multi sequence
P168 Memory of controller model no
P169 Software version
The rest parameter numbers are spare or vacant address.