5.7
Error code
1)
System error
code Error Description How to reset
100
Air pressure
The monitored air pressure is less or more
than
±5%
of the target over
3
seconds,
RESET button.
101
Motor hall
sensor Open
No motor hall sensor signal from the
screwdriver
RESET button
110
AMP
Over Current
Over current on AMP board circuit by over
load or wrong mechanical load.
Auto reset
after
1
sec.
111
SMPS Fault
by overload
Overload protection over
8A
on SMPS
power supply circuit.
Power Off, and
On after
1
min.
112
Overload alarm Over
5A
over
1
sec.
Auto reset
after
1
sec.
113
Driver overheat Over
80
℃
inside the driver
Auto reset
below
80
℃
114
Over Speed
Over rotation speed than the s et value.
Check the cable connection.
Auto reset
after
1
sec.
115
Wrong model
detected
Wrong model information of EEP-ROM in
driver. Check the EEP-ROM damage or
communication failure
RESET button
116
Wrong offset
detected
Wrong offset value over the range in the
driver is detected
Check the EEP-ROM damage or
communication failure
RESET button
117
Not compatible
driver
connected
The connected driver model is not
recognized by HDC. HDC latest firmware
upgrade is required
RESET button
118
Motor run
failed
Even the start signal is effective, motor
does not run
Repair required