8.
Auto fastening data output through USB port
(
P86)
Check mark on Enable on P86
(
auto fastening data output
),
then every fastening
data will be out at every event through RS-232 without data request command.
The output data consist of
13
fastening information as below
Each data is divided by comma(,) between data.
example
)
1.
StartofText
(
STX)
2.
Data
:m(
monitoring) data
3.
Serial no.
: 9039001 ( 2009,
March
)
4.
Fastening time
:1350
ms
5.
Preset
#:1
6.
Torque setting
:8.5
7.
Fastening torque
(
converted torque)
:8.4
8.
RPM setting
: 1700
rpm
9.
Fastening angle
:3.3
turn
10.
Motor temperature
:35.8
11.
Error code
: 000 (
No error, Fastening OK
)
if
301,
error
301
12.
Screw count
#:4
screws remained
13.
Motor current
:3.2
Ampere
14.
For
/
Rev
:
Fastening
(1),
Loosening
(0)
15.
Torque complete
:
Torque complete
(1),
No torque up
(0)
16.
Data check sum
:
See article
7.2.4
17.
End of Text
(
EXT)
12 3 4 5 6 7 8 9 10111213 14151617
STX data
Serial
no
Fastening
time
Preset
#
Torque
Converte
d
torque
RPM Angle
Motor
temp.
Error
code
count
no.
Motor
current
Fasten
Loosen
Torque
up
Check
Sum
data
ETX
m 9039001 01350 1 085 084 1700 033 0358 000 04 032 1 1 9
m9039001,01350,1,085,084,1700,033,0358,000,04,032,1,1,9