EasyManua.ls Logo

Moxa Technologies NPort 5110 Series - Page 46

Moxa Technologies NPort 5110 Series
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NPort 5110 Series User’s Manual Web Console Configuration
5-24
16 AT&D
Serial port DTR control
AT&D0=recognize DTE always
ready
AT&D1, AT&D2=reply DTE when
DTR On (default)
17 AT&F Restore manufacturer’s settings
18 AT&G Select guard time reply “OK” only
19 AT&R Serial port RTS option command reply “OK” only
20 AT&S Serial port DSR control reply “OK” only
21 AT&V View settings
22 AT&W
Write current settings to flash for
next boot up
S Registers
No. S Register Description & default value Remarks
1 S0 Ring to auto-answer (default=0)
2 S1 Ring counter (always=0) no action applied
3 S2
Escape code character (default=43 ASCII
“+”)
4 S3 Return character (default=13 ASCII)
5 S4 Line feed character (default=10 ASCII)
6 S5 Backspace character (default= 8 ASCII)
7 S6
Wait time for dial tone (always=2,
unit=sec)
no action applied
8 S7
Wait time for carrier (default=3,
unit=sec)
9 S8
Pause time for dial delay (always=2,
unit=sec)
no action applied
10 S9
Carrier detect response time
(always=6, unit 1/10 sec)
no action applied
11 S10
Delay for hang up after carrier
(always=14, unit 1/10 sec)
no action applied
12 S11
DTMF duration and spacing
(always=100 ms)
no action applied
13 S12
Escape code guard time
(default=50, unit 1/50 sec)
to control the idle time for “+++”

Table of Contents

Related product manuals