ATEX / IECEx Zone 2 Certification Information
.
1. ATEX Certificate Number: DEMKO 18 ATEX 2120X
IECEx Certificate Number: IECEx UL 18.0113X
2. Ambient Range:-30°C ≤ Ta ≤ +70°C, or -30°C ≤ Tamb ≤ +70°C
3. Certification String : Ex nA IIC T4 Gc
Rated Cable Temp 90 °C
4. Standards Covered:
EN 60079-0:2012+A11:2013
EN 60079-15:2010
IEC 60079-0, 6
th
Edition (2011-06) + Corr. 1 (2012-01) + Corr. 2
(2013-12) + I-SH 01 (2013-11) + I-SH 02 (2014-10), IEC 60079-
15, 4
th
Edition (2010-01) + I-SH 01 (2016-09)
5. Conditions for Safe Usage:
These devices shall be mounted in a suitable tool-accessible
ATEX/IECEx certified enclosure rated at least IP54 as defined in
EN/IEC 60529, Pollution Degree 2 and EN/IEC 60664-1, and shall
be used within their rated electrical and environmental ratings.
Grounding-wire Size
The minimum cross-sectional area of the grounding conductor should
be equal to that of the input cable.