Page #31 background imageLoading...
Page #31 background image
29
Table 2 Inverter Mode Specifications
INVERTER MODEL
1KVA
2KVA
3KVA
4KVA
5KVA
Rated Output Power
1KVA/0.8KW
2KVA/1.6KW
3KVA/2.4KW
4KVA/3.2KW
5KVA/4KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230Va 5%
Output Frequency
50Hz
Peak Efficiency
90%
Overload Protection
5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
12Vdc
24Vdc
48Vdc
Cold Start Voltage
11.5Vdc
23.0Vdc
46.0Vdc
Low DC Warning Voltage
@ load < 20%
11.0Vdc
22.0Vdc
44.0Vdc
@ 20% ≤ load < 50%
10.7Vdc
21.4Vdc
42.8Vdc
@ load ≥ 50%
10.1Vdc
20.2Vdc
40.4Vdc
Low DC Warning Return Voltage
@ load < 20%
11.5Vdc
23.0Vdc
46.0Vdc
@ 20% ≤ load < 50%
11.2Vdc
22.4Vdc
44.8Vdc
@ load ≥ 50%
10.6Vdc
21.2Vdc
42.4Vdc
Low DC Cut-off Voltage
@ load < 20%
10.5Vdc
21.0Vdc
42.0Vdc
@ 20% ≤ load < 50%
10.2Vdc
20.4Vdc
40.8Vdc
@ load ≥ 50%
9.6Vdc
19.2Vdc
38.4Vdc
High DC Recovery Voltage
14.5Vdc
29Vdc
58Vdc
High DC Cut-off Voltage
15.5Vdc
31Vdc
60Vdc
No Load Power Consumption
<15W
<20W
<50W
Saving Mode Power Consumption
<5W
<10W
<15W