J
jjamesAug 11, 2025
What to do if my MPP Solar PIP 1624 is beeping and the red light is on?
- WWilliam RiveraAug 12, 2025
If your MPP Solar Inverter is beeping continuously and the red LED is on, it could be due to several reasons: * **Overload error:** Reduce the connected load by switching off some equipment. * **Fault code 05:** Check if the wiring is well connected and remove any abnormal load. * **High temperature:** The internal converter component's temperature may be over 120°C. Ensure that the unit's airflow is not blocked and that the ambient temperature is not too high. * **Fault code 03:** Verify that the specifications and quantity of batteries meet the requirements. * **Fault code 01:** Replace the fan. * **Fault code 06:** Reduce the connected load or return the unit to a repair center. * **Fault code 08/09:** Return the unit to a repair center.