INVERTER / CHARGER
User Manual

Questions and Answers

  • K
    Katherine EsparzaAug 7, 2025
    What to do if MPP Solar Inverter unit shuts down automatically during startup?
    • R
      Robert Gonzalez DVMAug 7, 2025
      If your MPP Solar Inverter shuts down automatically during startup, it's likely because the battery voltage is too low (less than 1.91V/Cell). You should try to re-charge or replace the battery.
  • S
    Suzanne MelendezAug 12, 2025
    What to do if MPP Solar PIP-MS 1-5KVA Inverter has no response after power on?
    • W
      wagnerjamesAug 12, 2025
      If your MPP Solar Inverter doesn't respond after you power it on, it could be due to these reasons: * The battery voltage is far too low (less than 1.4V/Cell). * The battery polarity is reversed. To solve this: 1. Check if the batteries and wiring are properly connected. 2. Re-charge the battery. 3. Replace the battery.
  • B
    berrykeithAug 19, 2025
    What to do if internal relay of MPP Solar Inverter switches on and off repeatedly when turned on?
    • C
      Chelsea WeissAug 19, 2025
      If the internal relay of your MPP Solar Inverter switches on and off repeatedly when you turn it on, the battery may be disconnected. Check if the battery wires are properly connected.
  • A
    amy84Aug 25, 2025
    Why does my MPP Solar Inverter work in battery mode when mains exist?
    • M
      Ms. Jennifer BullockAug 25, 2025
      If your MPP Solar Inverter continues to use battery power even when mains are available, there are several possible reasons: * The input protector may have tripped. Check if the AC breaker has tripped and ensure the AC wiring is properly connected. * The AC power quality might be insufficient, especially from shore power or a generator. Verify that the AC wires aren't too thin or long. If using a generator, confirm it's working correctly and that the input voltage range setting is correct for your UPS Appliance. * The output source priority may not be set correctly. Change the output source priority to Utility first.
  • E
    edward89Oct 31, 2025
    What to do if MPP Solar Inverter buzzer beeps continuously and red LED is on?
    • C
      Christopher BradyOct 31, 2025
      A continuous beep and red LED on your MPP Solar Inverter indicates several potential issues: * The inverter may be overloaded (over 110%). Try reducing the load by switching off some equipment. * There may be a short circuit in the output. Check the wiring and remove any abnormal loads. * The internal converter component might be overheating (over 120°C, applicable to 1-3KVA models only). Ensure the unit's airflow isn't blocked and the ambient temperature isn't too high. * The battery could be over-charged. Return to repair center. * The battery voltage might be too high. Check if the battery specifications and quantity meet the requirements. * There could be a fan fault. Replace the fan. * The output may be abnormal (inverter voltage below 190Vac or higher than 260Vac). Red...

Summary

Safety Instructions

Product Overview

Installation

Battery Connection

Details how to connect battery packs to the inverter, including cable size recommendations.

AC Input;Output Connection

Explains how to connect AC input power and output connectors to the unit.

PV Connection

Describes the process of connecting PV modules to the inverter.

Operation

LCD Setting

Guide to configuring inverter settings through the LCD interface.

Fault Reference Code

Lists fault codes, their events, and corresponding icons for troubleshooting.

Warning Indicator

Details warning codes, events, audible alarms, and icon flashing for monitoring.

MPP Solar PIP-MS 1-5KVA Specifications

General IconGeneral
ModelPIP-MS 1-5KVA
Rated Power1-5 KVA
Transfer Time10 ms
WaveformPure Sine Wave
Overcharge ProtectionYes
Maximum PV Array Open Circuit Voltage145V
Maximum PV Array Power3000W
Frequency Range50Hz / 60Hz
Output Voltage230V
Efficiency (Peak)93%
Efficiency90%
Battery Voltage48V
Floating Charge Voltage54VDC
Maximum Charging Current60A
ProtectionsOverload, Short Circuit
Communication InterfaceRS232, USB
Operating Temperature0°C ~ 55°C
Humidity5% to 95% (Non-condensing)
CoolingFan