Table 2 Inverter Mode Specifications
INVERTER MODEL
1KVA 24V
2KVA 24V
3KVA 24V
2KVA 24V Plus
3KVA 24V Plus
1KVA 48V
3KVA 48V
2KVA 48V Plus
3KVA 48V Plus
4KVA
5KVA
Rated Output Power
1KVA/0.8KW
2KVA/1.6KW
3KVA/2.4KW
1KVA/
1
KW
2KVA/1.6KW
3KVA/2.4KW
4KVA/3.2KW
5KVA/4KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
110/120VAC
±5%*
or
230Vac±5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
90%
Overload Protection 5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage 24Vdc 48Vdc
Cold Start Voltage 23.0Vdc 46.0Vdc
Low DC Warning Voltage
@ load < 20%
22.0Vdc 44.0Vdc
@ 20% ≤ load < 50%
21.4Vdc 42.8Vdc
@ load ≥ 50%
20.2Vdc 40.4Vdc
Low DC Warning Return Voltage
@ load < 20%
23.0Vdc 46.0Vdc
@ 20% ≤ load < 50%
22.4Vdc 44.8Vdc
@ load ≥ 50%
21.2Vdc 42.4Vdc
Low DC Cut-off Voltage
@ load < 20%
21.0Vdc 42.0Vdc
@ 20% ≤ load < 50%
20.4Vdc 40.8Vdc
@ load ≥ 50%
19.2Vdc 38.4Vdc
High DC Recovery Voltage 29Vdc 58Vdc
High DC Cut-off Voltage 31Vdc
62Vdc 60Vdc
No Load Power Consumption <25W <50W
Saving Mode Power Consumption <10W <15W
*4KVA/5KVA only supports 230VAC system.