Solar charge controller MPPT-DC series User Manual
12.Technical Data
Page 5 of 5 pages
Battery
Parame-
ters
Panel
Parame-
ters
Load
Parame-
ters
System
Parame-
ters
MPPT2050-DC32Li MPPT3050-DC32LiG
20
A 30A
<Charging target voltage
3.0~5.0V(Programmable)
2.9~4.9V(Programmable)
2.4~4.0V(Programmable)
2.6~4.2V(Programmable)
Lithium
Yes, Slow, No(Programmable)
10V
25V 34V*1
65W 100W
(Vb+1.0V)~Voc*0.9 *2
1.0~3.0V (Programmable)
0~30min(Programmable)
0.1~1.5A(Programmable) 0.1~3A(Programmable)
12 34
1~25W 1~60W
50mA(Dimming)
±2%
0~100%(Programmable)
Yes, No(Programmable)
2.8~Charging target voltage(Programmable)
5~40%(Programmable)
>99.9%
93.0% 95.0%
93.0% 95.0%
<23mA@3.2V 50mA@3.2V
85.8 * 81 * 23.1mm 112 * 76 * 30mm
280g 450g
-35~+60℃
0~100%RH
IP67
4000m
~ V
Item
Max Charging Current
MPPT Charging Voltage
Charging voltage target
Charging voltage recovery
Low voltage disconnect
Low voltage reconnect
Battery Type
0℃ Charging protection
Max volt on Bat. Terminal
Max volt on PV terminal
Max input power
MPPT tracking range
Dusk/Dawn detect volt.
Day/Night delay time
Output Current
Output Voltage
Output power
Min Current
Current precision
Dimming
Auto dimming
Voltage of start dimming
Dimming percentage
Max tracking efficiency
Max charge conversion
Max LED driver efficiency
Self consumption
Dimensions
Weight
Ambient temperature
Ambient humidity
Protection degree
Max Altitude
*1.This value represents the maximum voltage of the solar panel at the minimum operating ambient temperature.
*2.Voc means the open circuit voltage of the solar panel.
*3.The product without tail is infrared communication,Model name +"G", means 2.4G communication.