This document is an installation, operation, and maintenance manual for Mr. Steam residential steambath generator systems, covering models MS90E – MS400E and MSSUPER1E – 6E.
Function Description:
The Mr. Steam steambath generator systems are designed to produce steam for residential steambath enclosures. These units heat water to create steam, which is then delivered to a steam head within the steambath room, providing a relaxing and therapeutic steam bathing experience. The systems are controlled by various Mr. Steam controls (iSteam®, AirTempo®, iTempo/Plus®, iTempo®, Home Wizard®, and iGenie®), which allow users to set temperature and duration. Optional features like AutoFlush® and AromaSteam® enhance the user experience and system maintenance.
Important Technical Specifications:
- Models Covered: MS90E, MS150E, MS225E, MS400E, MS-SUPER 1E, MS-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E.
- Power Supply: Available in 240V/1PH, 208V/1PH, and other voltages/phases.
- MS90E: 5 KW, 21 Amps (240V/1PH), 10 AWG wire size, 100 Total Adj. Room Vol. (cu. ft.).
- MS150E: 6 KW, 25 Amps (240V/1PH), 8 AWG wire size, 150 Total Adj. Room Vol. (cu. ft.).
- MS225E: 7.5 KW, 32 Amps (240V/1PH), 8 AWG wire size, 225 Total Adj. Room Vol. (cu. ft.).
- MS400E: 9 KW, 38 Amps (240V/1PH), 8 AWG wire size, 360 Total Adj. Room Vol. (cu. ft.).
- MS SUPER 1E: 10 KW, 42 Amps (240V/1PH), 8 AWG wire size, 475 Total Adj. Room Vol. (cu. ft.).
- MS SUPER 2E: 12 KW, 50 Amps (240V/1PH), 6 AWG wire size, 575 Total Adj. Room Vol. (cu. ft.).
- MS SUPER 3E: 15 KW, 63 Amps (240V/1PH), 4 AWG wire size, 675 Total Adj. Room Vol. (cu. ft.).
- MS SUPER 4E: 20 KW, 84 Amps (240V/1PH), 8 AWG wire size, 875 Total Adj. Room Vol. (cu. ft.). (Comprises two MS SUPER 1E units).
- MS SUPER 5E: 24 KW, 100 Amps (240V/1PH), 6 AWG wire size, 1075 Total Adj. Room Vol. (cu. ft.). (Comprises two MS SUPER 2E units).
- MS SUPER 6E: 30 KW, 125 Amps (240V/1PH), 4 AWG wire size, 1275 Total Adj. Room Vol. (cu. ft.). (Comprises two MS SUPER 3E units).
- Dimensions (L x H x D):
- MS90E-MS400E: 14.5" x 14.75" x 6.75".
- MS SUPER 1E-3E: 17" x 18.5" x 7.875".
- MS SUPER 4E-6E: 17" x 18.5" x 7.875" x 2 (as they are tandem units).
- Water Usage: Ranges from 0.67 gallons (MS90E) to 4.0 gallons (MS SUPER 6E) based on 20 minutes of operation.
- Plumbing Connections:
- Water Inlet: 3/8" NPT.
- Steam Outlet: 1/2" NPT.
- Safety Valve: 3/4" NPT.
- Manual Drain Valve: 1/2" NPT.
- AutoFlush Valve (optional): 1/2" NPT.
- Control Cable Length: Standard 30 feet, optional 60 feet available. Maximum cable length is 60 feet.
- Clearances: Minimum 12 inches at both ends and top for servicing. Zero clearance from combustible surfaces.
- Water Quality: Recommended feedwater quality includes hardness (1-5 gpg), P. Alkalinity (85-410 ppm), T. Alkalinity (200-500 ppm), and pH (8.0-11.4). An AutoFlush® system is recommended for generator longevity in hard water areas.
Usage Features:
- Controls: Compatible with Mr. Steam iSteam®, AirTempo®, iTempo/Plus®, iTempo®, Home Wizard®, and iGenie® controls for setting temperature and duration.
- Steam Head: Round or square AromaSteam steamhead with an oil well for essential oils. Should be located 6-12 inches above the floor (or 6 inches above tub top edge for tub/shower enclosures) and away from direct contact with bathers or door seals.
- AromaSteam®: Optional electronic oil delivery system for infusing essential oils into the steam.
- Express Steam® (factory installed): A low-power heating element and thermostat keep water warm for quicker steam production.
- Tandem Operation: MS SUPER 4E, 5E, and 6E models consist of two or more generators operating in tandem, controlled by a single iTempo/Plus® control.
- Safety Features:
- Warning labels for hot surfaces, slippery wet surfaces, and hyperthermia risks.
- Recommendations for consulting a physician for pregnant individuals, those with heart conditions, high blood pressure, diabetes, or those on medication.
- Automatic shut-off when desired temperature is reached or duration ends.
- Safety valve to prevent overpressure.
- Warning against children under 16 using the steambath.
Maintenance Features:
- Manual Drain Valve: Should be opened fully every 2 months (or more often in hard water areas) to flush out accumulated materials, salts, and particles. Water should be allowed to cool for 2-3 hours before draining to prevent scalding.
- AutoFlush® System (optional): Automatically drains the generator after each use, with a time delay to allow water to cool. This feature is recommended for generator longevity, especially in hard water areas.
- Control and Steamhead Cleaning: Use only mild soap and water on a soft cloth. Avoid abrasive cleansers.
- Troubleshooting: The manual provides a detailed troubleshooting guide with system status codes (H20, Prr1, Prr2, Err1, Err2, Errb, Err7) and suggested remedies, along with a liquid level control board explanation of LED indicators (Green, Yellow, Red) and a test button.
- Parts Identification and Replacement: Diagrams and a comprehensive list of replacement parts are provided for various generator components, including heating elements, contactors, transformers, and valves.
- Warranty: Information on how to view and download the warranty and register the product is available online.