NOTE ON PIPE LENGTH
The length of refrigerant piping will affect the performance and energy efficiency of the unit. Nominal
efficiency is tested on units with a pipe length of 16.5 ft (5 m). In North America, the standard pipe
length is 25 ft (7.5 m). A minimum pipe run of 9.8 ft (3 m) is required to minimize vibration and
excessive noise.
Refer to the table below for specifications on the maximum length and drop height of piping.
Maximum Length and Drop Height of Refrigerant Piping per Unit Model
Model Capacity (BTU/h) Max. Length (ft/m) Max. Drop Height (ft/m)
R410A Inverter Split
Air Conditioner
< 15,000 82 ft (25 m) 33 ft (10 m)
66 ft (20 m)
82 ft (25 m)
98 ft (30 m)
213 ft (65 m)
98.5 ft (30 m)
164 ft (50 m)
≥ 15,000 and < 24,000
≥ 24,000 and < 36,000
36,000
2. Using a pipe cutter, cut the pipe a little longer than
the measured distance.
3.
Make sure that the pipe is cut at a perfect 90° angle.
Refer to Fig. 6.1 for bad cut examples.
Oblique Rough Warped
Fig. 6.1
90°
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to
cut and flare them properly. This will ensure efficient
operation and minimize the need for future mainte-
nance.
1. Measure the distance between the indoor and
outdoor units.
6
Refrigerant Piping Connection
Connection Instructions
– Refrigerant Piping
When connecting the refrigerant piping, DO NOT let substances or gases other than the specified refrigerant
enter the unit. The presence of other gases or substances will lower the unit’s capacity,and can cause
abnormally high pressure in the refrigeration cycle. This could cause an explosion and/or injury.

Other manuals for MrCool A-09-HP-C-115B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool A-09-HP-C-115B and is the answer not in the manual?

MrCool A-09-HP-C-115B Specifications

General IconGeneral
BrandMrCool
ModelA-09-HP-C-115B
CategoryHeat Pump
LanguageEnglish

Related product manuals