Gas Detected | Hydrogen Sulfide (H2S) |
---|---|
Display | LCD |
Resolution | 1 ppm |
Audible Alarm | Yes |
Visual Alarm | Yes |
Vibrating Alarm | Yes |
Ingress Protection | IP67 |
Response Time | T90 < 15 seconds |
Operating Temperature | -20°C to 50°C |
Alarm Setpoints | Adjustable |
Battery Type | Replaceable lithium battery |
Accuracy | ± 5% of reading |
Detection Range | 0 to 100 ppm |
Battery Life | Up to 2 years |
Guidelines for the proper and intended use of the ALTAIR PRO gas detector.
MSA's disclaimer of liability for inappropriate use or unauthorized alterations to the product.
Essential safety instructions and measures for operators and instrument functionality.
Visual guide to the ALTAIR PRO gas detector, identifying key components and their functions.
Explanation of the symbols and indicators displayed on the ALTAIR PRO screen.
Details on battery warnings, shutdown modes, and actions to take when battery levels are low.
How to monitor Carbon Monoxide (CO) and Hydrogen Sulphide (H2S) with alarm setpoints.
Procedure for monitoring oxygen levels with alarm setpoints for enrichment or depletion.
Information on normal operation, indicators for weakening and flat batteries, and usage restrictions.
Manual and software-based methods for adjusting alarm thresholds for different gases.
Step-by-step guide for powering on the ALTAIR PRO, including functional tests and setup prompts.
Detailed procedure for measuring CO and H2S, including alarm conditions and setpoints.
Explanation of High, STEL, and TWA alarms for toxic gases and their response.
Procedure for measuring oxygen, including alarm setpoints and common causes of false alarms.
How to access and view test gas mode, peak readings, STL, and TWA data.
Accessing instrument data including test mode, software version, and alarm setpoints for Steel Mill version.
Instructions for safely powering down the ALTAIR PRO gas detector.
Details on recording events, stored logs, periodic logging, and connecting the instrument to a PC.
Procedures for checking instrument confidence, performing alarm tests, and conducting bump tests.
Steps for calibrating the ALTAIR PRO, including requirements and procedures for toxic gases.
Detailed steps for calibration, including gas value checks, error handling, and self-tests.
Specific instructions for calibrating the oxygen sensor, including conditions and checks.
Guide to identifying and resolving common problems using error codes and reactions.
Step-by-step instructions for safely removing and replacing the instrument's battery.
Procedure for replacing a sensor, including safety precautions and recalibration requirements.
Detailed specifications including weight, dimensions, alarms, battery, sensor, and measurement ranges.
Information on operational/storage temperature, humidity, IP rating, and product warranty.
Details of European and international certifications and compliance standards for the ALTAIR PRO.
Lists test gases for self-test/calibration and typical performance metrics for Oxygen and Toxic gases.
Details on session and periodic datalogging, including event information and transmission methods.