3103-1001 Rev. 0 6
Flow System:
Flow Scheme “Look-Ahead Bypass
Connection size and thread:
Sample Inlets and Exhausts - 1/8" NPTF
Drain - 1/8" NPTF
Sample Line Tubing - 500' max, with 0.250" OD, 0.175 ID tubing
Sample Line Flow Rate:
20 SCFH typical, No Load
10 SCFH typical, Full Load
Temperature:
Operating- 35 to 95
o
F (0 to 35
o
C)
Non-Operating- 14 to 140
o
F (-10 to 60
o
C)
Sample- 0 to 140
o
F (-17 to 60
o
C)
Humidity:
5 to 85% RH non-condensing