EasyManuals Logo

MSI MS-7125 User Manual

MSI MS-7125
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
3-11
BIOS Setup
CAS# Latency (Tcl)
When the Timing Mode is set to [Manual], the field is adjustable.This controls
the CAS latency, which determines the timing delay (in clock cycles) before
SDRAM starts a read command after receiving it. Settings: [Auto], [CL=2.0],
[CL=2.5], [CL=3.0]. [CL=2.0] increases the system performance the most while
[CL=3.0] provides the most stable performance.
Min RAS# Active Time (Tras)
When the Timing Mode is set to [Manual], the field is adjustable. This setting
determines the time RAS takes to read from and write to a memory cell. Setting
options: [Auto], [5T], [6T], [7T], [8T], [9T], [10T], [11T], [12T], [13T], [14T], [15 T].
RAS# to CAS# delay (Trcd)
When the Timing Mode is set to [Manual], the field is adjustable. When DRAM
is refreshed, both rows and columns are addressed separately. This setup
item allows you to determine the timing of the transition from RAS (row address
strobe) to CAS (column address strobe). The less the clock cycles, the faster
the DRAM performance. Setting options: [Auto], [2T], [3T], [4T], [5T], [6T], [7T].
Row Precharge Time (Trp)
When the Timing Mode is set to [Manual], the field is adjustable. This item
controls the number of cycles for Row Address Strobe (RAS) to be allowed to
precharge. If insufficient time is allowed for the RAS to accumulate its charge
before DRAM refresh, refreshing may be incomplete and DRAM may fail to
retain data. This item applies only when synchronous DRAM is installed in the
system. Available settings: [Auto], [2T], [3T], [4T], [5T], [6T], [7T].
Row cycle time (Trc)
When the Timing Mode is set to [Manual], the field is adjustable. The row
cycle time determines the minimum number of clock cycles a memory row takes
to complete a full cycle, from row activation up to the precharging of the active
row. Available settings: [Auto], [7T]~[22T].
Row refresh cyc time (Trfc)
When the Timing Mode is set to [Manual], the field is adjustable. Auto-refresh
-active to RAS#-active or RAS# auto-refresh. Available settings: [Auto], [9T],
[10T] ~ [24T].

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSI MS-7125 and is the answer not in the manual?

MSI MS-7125 Specifications

General IconGeneral
BrandMSI
ModelMS-7125
CategoryMotherboard
LanguageEnglish

Related product manuals