Temposonics
®
R-Series V Analog
Operation Manual
I 31 I
Fig. 46: Adjusting the error output value
Fig. 47: Adjusting magnet 1 set point positions
7. The last setting for channel one output is for the error output
value. For this example, the factory default value of 20.7 mA
is changed to 20.5 mA. Confirm your changes by clicking the
SUBMIT button.
8. The factory setting for channel one function is magnet 1 position.
For most all applications this setting is not typically changed.
For sensors ordered with 2 output channels, the Channel Two
Function setting can be used for the other available output
functions. These are: magnet 2 position, magnet 1 speed,
magnet1 velocity, magnet 1 reverse position, temperature inside
the sensor electronics housing, and the differential between
magnet 1 and 2.
For this example with 1 output channel, the next setting can be
used to adjust the magnet 1 positions for set point one (start of
stroke) and set point two (end of stroke). Click on “Read Magnet”
to retrieve the currently measured position value for magnet 1.
Confirm your changes by clicking the SUBMIT button.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems Temposonics R V Series and is the answer not in the manual?

MTS Systems Temposonics R V Series Specifications

General IconGeneral
BrandMTS Systems
ModelTemposonics R V Series
CategoryAccessories
LanguageEnglish

Related product manuals