3. Unscrew cut-out oil filter with oil filter
wrench.
4. Clean sealing surface on connecting piece.
5. Check condition of new oil filter sealing ring
and coat it with oil.
6. Fit SOLAS shield (→ Page 60).
7. Screw on and tighten new oil filter by hand.
8. Replace other oil filters in the same way.
9. Switch filter to normal position.
10. After each oil change and filter replacement,
crank engine with starting system
(→ Page 68).
11. Check oil level (→ Page 98).
Replacing oil filter with the engine running
1. Reduce engine speed to <1100 rpm.
2. Unscrew cut-out oil filter with oil filter wrench.
3. Clean sealing surface on connecting piece.
4. Check condition of new oil filter sealing ring and coat it with oil.
5. Fit SOLAS shield (→ Page 60).
6. Screw on and tighten new oil filter by hand.
7. Replace other oil filters in the same way.
8. Switch filter to normal position.
9. Check oil level (→ Page 98).