4.2 Engine – Putting into operation after scheduled out-of-service-
period
Preconditions
☑Engine is stopped and starting disabled.
Putting into operation
Item Action
Lube oil system Check engine oil level (→ Page 97).
Coolant circuit Check coolant level (→ Page 103).
Coolant circuit Heat engine coolant with coolant preheating unit.
Fuel prefilter Drain water and contaminants (→ Page 86).
Battery-charging generator
drive
Check condition of drive belt (→ Page 113).
Engine Control Unit ECU Check plug connections (→ Page 118).
Engine Interface Module EIM Check plug connections (→ Page 120).
Engine Monitoring Unit EMU Check plug connections (→ Page 119).
MS150119/00E 2014-08 | Operation | 49
TIM-ID: 0000002689 - 003

Table of Contents