EasyManua.ls Logo

MTU 16 V 2000 M92 - Page 74

MTU 16 V 2000 M92
141 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10V2000
Position Cylinder 1 2 3 4 5 6 7 8 9
Firing TDC in cylinder A1 Bank A E A - - - - - A E -
Bank B E - - - - A E A E -
Overlap TDC in cylinder A1 Bank A - - E A E A E - - A
Bank B - A E A E - - - - A
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
12V2000
Position Cylinder 1 2 3 4 5 6 7 8 9
Firing TDC in cylinder A1 Bank A E A E - - A E - - A - -
Bank B E - - - - A E - E
A
- A
Overlap TDC in cylinder A1 Bank A - - - A E - - A E - E A
Bank B - A E A E - - A - - E -
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
16V2000
Position Cylinder 1 2 3 4 5 6 7 8 9
Firing TDC in cylinder A1 Bank A E A - A - A E - - A E - - - - -
Bank B E - - A - - E - E
A
E - E
A
- A
Overlap TDC in cylinder A1 Bank A - - E - E - - A E - - A E
A
E A
Bank B - A E - E A - A - - - A - - E -
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
18V2000
Position Cylinder 1 2 3 4 5 6 7 8 9
Firing TDC in cylinder A1 Bank A E A E - - A E - - A - - - A - - - -
Bank B - A - A - - E A - - E
A
E - E A E -
Overlap TDC in cylinder A1 Bank A - - - A E - - A E - E A E - E A E A
Bank B E - E - E A - - E
A
- - - A - - - A
“E” = inlet valve clearance adjustment permitted, “A” = exhaust valve clearance adjustment permitted
4. Use feeler gauge to determine the distance between valve bridge and rocker arm.
5. If the deviation from the reference value exceeds 0.1 mm, adjust valve clearance.
74 | Task Description | M015700/06E 2012-06