Number of cylinders 12
16
Number of inlet valves per cylinder 2 2
Number of exhaust valves per cylinder 2 2
Standard housing connecting flange (engine main PTO) SAE 0 0
Coolant system (HT circuit)
Number of cylinders 12
16
Coolant temperature (at engine connection: outlet to cooling
equipment)
A °C 100 100
Coolant temperature after engine, alarm R °C 106 105
Coolant temperature after engine, shutdown L °C 108 107
Coolant antifreeze content, max. L % 50 50
Pressure loss in off-engine cooling system, max. L bar 1.0 1.0
Coolant system (LT circuit)
Number of cylinders 12
16
Coolant temperature before intercooler (at engine connection:inlet
from cooling equipment)
A °C 45 45
Coolant antifreeze content, max. L % 50 50
Pressure loss in off-engine cooling system, max. L bar 1.0 1.0
Lube-oil system
Number of cylinders 12
16
Lube-oil operating temperature before engine, from R °C 80 80
Lube-oil operating temperature before engine, to R °C 103 104
Lube-oil temperature before engine, alarm L °C 103 105
Lube-oil temperature before engine, shutdown L °C 105 107
Lube-oil operating pressure before engine, from R bar 7.6 7.8
Lube-oil operating pressure before engine, to R bar 9.0 9.6
Fuel system
Number of cylinders 12
16
Fuel pressure at engine inlet connection, min. (when engine is
starting)
L bar -0.5 -0.5
Fuel pressure at engine inlet connection, max. (when engine is
starting)
L bar 0.5 0.5
General operating data
Number of cylinders 12
16
Cold start capability: air temperature (w/o start aid, w/o preheat-
ing) - (case A)
R °C 0 0
Firing speed, from R rpm 100 100
Firing speed, to R rpm 120 120