Fault
code no. Full designation Meaning Action
Setting parame-
ter no.
229 AL Stop Camshaft Sen-
sor Defect
Engine stop due to camshaft
sensor fault (and a previous
crankshaft sensor fault in the
same operating cycle). Alarm
configuration parameter, see
PR 2.8008.100 for explana-
tion.
Check connector
and wiring to sensor
B1, replace as nec-
essary. Fault is rec-
tified when engine is
restarted. If cam-
shaft and crankshaft
sensor are both faul-
ty, check connector
and wiring to sensor
B1 and B13. Re-
start. Fault is recti-
fied when engine is
restarted, contact
Service if this is not
the case.
1.8004.562
230 SD Crankshaft Speed SD alarm configuration,
crankshaft sensor faulty,
short circuit or wiring dam-
age, engine remains opera-
tional.
Check sensor and
wiring (B13), at-
tempt restart, fault
may be rectified
when engine is re-
started. Contact
Service if this is not
the case
1.8004.498
231 SD Camshaft Speed SD alarm configuration, cam-
shaft sensor faulty, short cir-
cuit or wiring damage, engine
remains operational.
Check sensor and
wiring (B1), attempt
restart, fault may be
rectified when en-
gine is restarted.
Contact Service if
this is not the case.
1.8004.499
240 SD P-Fuel SD alarm configuration, en-
gine remains operational,
fuel pressure sensor faulty,
short circuit or wiring dam-
age.
Check sensor and
wiring (B34), replace
as necessary.
1.8004.565
245 SD ECU Power Supply
Voltage
SD alarm configuration, inter-
nal engine governor fault.
Execute engine gov-
ernor self-test, re-
place engine gover-
nor in case of fault.
2.8006.589
266 SD Speed Demand SD alarm configuration, ana-
log speed setting faulty,
short circuit or wiring dam-
age.
Check speed setting
transmitter and wir-
ing, replace as nec-
essary. Fault is rec-
tified when engine is
restarted.
2.8006.586
269 SD Loadp.Analog filt. SD alarm configuration, fil-
tered analog signal of load
pulse not available, short cir-
cuit or wiring damage
Check wiring, re-
place as necessary.
Fault is rectified
when engine is re-
started.
2.8006.588
52 | Troubleshooting | MS15018/03E 2016-02