8.21.4 Engine Monitoring Unit EMU 7 – Plug connection check
Preconditions
☑ Engine is stopped and starting disabled.
Checking EMU plug connections
1. Check both connectors on EMU (2) for firm
seating. Ensure that the clips (1) are engag-
ed.
2. Check screws (3) of cable clamps on EMU (2)
for firm seating. Ensure that cable clamps are
not faulty.
MS150060/04E 2016-02 | Accessories for (Electronic) Engine Governor / Control System | 135