8.8.3 Fuel prefilter – Draining
Preconditions
Engine is stopped and starting disabled.
WARNING
Liquid or gaseous media, e.g. fuel, are poisonous.
Escaping vapors of highly volatile media, e.g. fuel or ether.
Risk of fatal injury through swallowing; risk of poisoning through inhalation; irritation to eyes
and skin!
Seek medical attention immediately; do not induce vomiting.
Do not inhale vapors or mist.
Wear protective clothing, protective gloves, and safety glasses.
If contact is made with skin, wash off with water and soap.
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
Draining fuel prefilter
1. Switch off filter which is to be drained (A or
B):
1 Filter A cut out
2 Filter B cut out
92 | Fuel Filter | MS150060/04E 2016-02