EasyManua.ls Logo

MTU 8V2000Mx4x - Page 142

MTU 8V2000Mx4x
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Preamble
2 ECU current path failed (S1)
3 MCS current path failed
(S2)
4 EMU current path failed
(S3)
5 Starter voltage: Terminal
30, 31 not connected and
PR 10.0600.001 has value
1 or 2 (S4)
6 VSP current path failed (S5)
7 SLD current path failed (S6)
8 DDV current path failed (S7)
9 Gear monitoring current
path failed (S8)
10 Emergency stop current
path failed – 24 V internal
(S9)
11 ES pushbutton current path
failed – 24 V external (S10)
12 Key switch current path
failed (S11)
13 SDAF 1 and 2 current path
failed (S12)
14 PIM current path failed
(S13)
15 Spare current path failed
(S14) (only for EIM with
ECU 7)
The failed current paths are signaled consecutively following the preamble (1) (LED on for 4 seconds). There
is a pause lasting 4 seconds in between.
142 | Accessories for (Electronic) Engine Governor / Control System | MS150060/04E 2016-02