Functions:
Starter control (start repetition, tooth alignment, starter protection)
Generator monitoring
Open bus interface to the plant (SAE J1939)
Emergency stop function with line break monitoring
Redundant power supply
Optional control of emergency-air shutoff flaps
Key switch logic
Interface to ECU and EMU
MCS5 dialog interface
Control of an MTU lube-oil priming pump (power components in separate MTU PPC Box)
Connection facility for an MTU Local Operating Station (LOS)
Serial RS422 interface for diagnosis
The engine interface is divided into two parts. The first part is integrated in the engine wiring harness via the
62-pole Tyco connector X52. The second part is formed by those signals involving a higher current. Such
signals are routed out via M threaded pins and are also integrated in the engine wiring harness.
Functions
ECU supply
EMU supply
Plant signals (ECU7 connector X1)
Bus interface (2x MCS5 CAN)
CAN dialog output (1x MCS5 CAN)
ECU and EMU emergency stop
Electric starter
Terminal 45 starter A/B (engaged)
Pneumatic starter
Starting air pressure valve
Starting air pressure sensor
Barring device (Barring Gear 1 and 2)
Generator (with exciter control)
Optional emergency-air shutoff flaps
Activation of SDAF 1+2
Feedback from SDAF 1+2
Electronic engine control unit (ECU)
Closed-loop control:
Engine speed
High-pressure fuel
Valve gear:
Injection (fuel pressure, injection timing, injection duration, operating status)
Sequential turbocharging (cutting-in and out) with secondary turbocharger
Engine protection with multi-stage safety systems:
Power reduction
Power limitation
Emergency stop