Raw water circuit (open circuit)
Number of cylinders 10
Raw water pump: Inlet pressure, min. L bar -0.4
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in engine-external raw water system, max. L bar 1.2
Lube oil system
Number of cylinders 10
Lube oil operating temperature before engine, from R °C 75
Lube oil operating temperature before engine, to R °C 83
Lube oil operating pressure before engine, from R bar 8.0
Lube oil operating pressure before engine, to R bar 9.0
Lube oil operating pressure (low idle) (meas. point: before engine) R bar 2.5
Fuel system
Number of cylinders 10
Fuel pressure at engine inlet connection, min. (when engine is starting) L bar -0.3
Fuel pressure at engine inlet connection, min. (during engine operation) L bar -0.3
Fuel pressure at engine inlet connection, max. (when engine is starting) L bar +0.25
Fuel supply flow, max. R liters/min 5.9
General operating data
Number of cylinders 10
Firing speed, from R rpm 100
Firing speed, to R rpm 120
Starter (electric)
Number of cylinders 10
Rated starter voltage (standard design) R V= 24
Inclinations - standard oil system (reference: waterline)
Number of cylinders 10
Longitudinal inclination, continuous max. driving end down (option: max. oper-
ating inclinations)
L Degrees
(°)
15
Longitudinal inclination, temporary max. driving end down (option: max. oper-
ating inclinations)
L Degrees
(°)
20
Longitudinal inclination, continuous max. driving end up (option: max. operat-
ing inclinations)
L Degrees
(°)
5
Longitudinal inclination, temporary max., driving end up (option: max. operat-
ing inclinations)
L Degrees
(°)
10
Transverse inclination, continuous max. (option: max. operating inclinations) L Degrees
(°)
22.5
Transverse inclination, temporary max. (option: max. operating inclinations) L Degrees
(°)
35
MS150060/04E 2016-02 | Technical Data | 41
TIM-ID: 0000010811 - 004