EasyManua.ls Logo

MTU MS150033/05E - Page 24

MTU MS150033/05E
189 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Number of cylinders 12 16
Gas type: natural gas X X
Methane number, min. L 70 70
Table 6: General conditions (for max. power)
Consumption
Number of cylinders 12 16
Lube oil consumption after 1000 h runtime g/kWh 0.2 0.2
Table 7: Consumption
Model-related data (basic design)
Number of cylinders 12 16
Operating method: Four-stroke cycle, Otto engine, single-acting X X
Combustion method: Mixture charging, spark ignition X X
Number of cylinders 12 16
Cylinder arrangement: V angle Degrees
(°)
90 90
Bore mm 170 170
Stroke mm 210 210
Displacement of a cylinder Liters 4.77 4.77
Total displacement Liters 57.20 76.27
Compression ratio 12.9 12.9
Standard housing connecting flange (engine main PTO) SAE 00 00
Table 8: Model-related data (basic design)
Coolant system (HT circuit)
Number of cylinders 12 16
Coolant temperature (at engine connection: outlet to cooling
equipment) (w/o antifreeze)
A °C 90 90
Coolant temperature (at engine connection: inlet from cooling
equipment (w/o antifreeze)
A °C 78 78
Coolant temperature after engine, warning R °C 95 95
Coolant temperature after engine, shutdown L °C 98 98
Coolant temperature to enable load application, min. L °C 40 40
Coolant antifreeze content, max. L % 50 50
Coolant pump: Volumetric flow L m³/h 56 65
Filling pressure in cooling system (cold) R bar 0.5 0.5
Pressure in cooling system, max. L bar 6.0 6.0
Pressure loss over engine (at nominal flow rate 7.27) bar 2.1 2.0
Thermostat: Starts to open R °C 68 68
Thermostat: Opening stops (thermostat fully open and bypass
closed)
A °C 74 74
Table 9: Coolant system (HT circuit)
24 | Product Summary | MS150033/05E 2013-10
TIM-ID: 0000010826 - 002

Table of Contents