EasyManuals Logo

Muller Elektronik SPRAYDOS User Manual

Default Icon
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Copyright Müller-Elektronik GmbH & Co.KG, Installation and operating instructions SPRAYDOS (07.2016) Page - 19 -
> Press and simultaneously
> While stationary switch on the field sprayer using until the measuring jug has been filled with e.g. 2 litres (the
computer counts the flow meter impulses). All sections must be open.
> Switch off the sprayer using
> Determine the amount sprayed
(read the quantity in the measuring jug and multiply by the number of nozzles)
> Set the value calculated using the keys and
> Press to transfer the new value
> The computer has now calculated the "impulses / litres"
6.2.6 "Type" key
This key is used to enter 2 functions. The number before the comma determines the manifold type. The 2 positions after
the comma determine the control constant.
> Press
> Set the value using the keys and
> Press to transfer the new value
6.2.6.1 Manifold type
The manifold type is communicated to the computer via the number before the comma.
The following manifold types are taken into account (in the example a control constant of 15 is assumed):
Parameter
Manifold type
0.15
Balanced pressure manifold without reflux measurement
1.15
Manifold without balanced pressure function.
2.15
Balanced pressure manifold with reflux measurement
3.15
Spraying devices without balanced pressure function
Manifold type (number before the comma)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Muller Elektronik SPRAYDOS and is the answer not in the manual?

Muller Elektronik SPRAYDOS Specifications

General IconGeneral
BrandMuller Elektronik
ModelSPRAYDOS
CategoryDesktop
LanguageEnglish

Related product manuals