EasyManua.ls Logo

Multi-Tech MTA128ST-USB - Data Call Commands

Default Icon
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
Chapter 4 - AT Commands, S-Registers, and Result Codes
Data Call Commands
A Answer
D Dial
DSn Dial Stored telephone number
&Jn Channel Bundling
H Hang up
In Display product information
On Return on-line
@Config Start ConfigMenu
Command Implementation
Command: AT
Function: Attention Code
Values: n/a
Default: n/a
Description:The attention code precedes all command strings except the A/ command
and escape codes.
Command: RETURN
Function: Command Execution
Default: n/a
Values: n/a
Description:Press RETURN (ENTER) to execute a command. In command examples,
RETURN frequently is abbreviated <cr>.
Command: +++AT<cr>
Function: In-Band Escape Code
Values: ASCII
Default: + (43)
Description:Makes TA enter command mode (without disconnecting the call) when it is
on-line with a remote device. Default escape code is three
+
characters
followed by the letters
AT
, up to 80 command characters and a RETURN
(press Enter). The TA escapes to command mode, executes any commands
in the string, and then remains in command mode. Use
S2=
command to
change the escape character.
Command:
<break>AT<cr>
Function: Out-of-Band Escape Code
Values: n/a
Default: n/a
Description:Places TA in command mode while remaining on-line. Enter a break signal,
the letters
AT,
up to 80 command characters, and a RETURN (press Enter).

Table of Contents