OPERATION AND PARTS MANUAL
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
To find the latest revision of this
publication, visit our website at:
www.multiquip.com
SERIES
MODEL MTX60HD
TAMPING RAMMER
(HONDA GX100UKRBF GASOLINE ENGINE)
Revision #3 (10/26/18)

Questions and Answers

  • M
    marywatsonAug 19, 2025
    Why is my MULTIQUIP MTX60HD engine overheating?
    • A
      andersonjamesAug 19, 2025
      If your MULTIQUIP Vibratory rammers & tampers engine overheats, it could be due to several reasons. The spark plug heat value might be incorrect, so replace it with the correct type. The fuel type could be wrong, so replace it with the correct type. Dirty cooling fins can also cause overheating, so clean them. Check for any restrictions in the intake air and clear any dirt or debris, replacing air cleaner elements if needed. Finally, ensure the oil level is at the proper level, adjusting if it's too low or too high.
  • J
    Jody SantosAug 21, 2025
    What to do if MULTIQUIP MTX60HD Vibratory rammers & tampers is hard to start with low compression?
    • F
      frederick92Aug 21, 2025
      If your MULTIQUIP Vibratory rammers & tampers is difficult to start, even with fuel and spark, but low compression, it could be due to several reasons. The suction or exhaust valve might be stuck or protruded, in which case you should reseat the valves. The piston ring or cylinder might be worn, requiring replacement of the piston rings or the piston. The cylinder head or spark plug might not be tightened properly, so torque the cylinder head bolts and spark plug. Lastly, the head gasket or spark plug gasket could be damaged, requiring replacement.
  • L
    Lori LeeAug 23, 2025
    Why is my MULTIQUIP MTX60HD Vibratory rammers & tampers weak and misfiring?
    • E
      Emily DuffyAug 23, 2025
      If your MULTIQUIP Vibratory rammers & tampers is weak in power but misfires, even with proper compression, there might be water in the fuel system. In this case, flush the fuel system and replace it with the correct type of fuel. The spark plug could be dirty, so clean or replace it. Alternatively, the ignition coil might be defective, requiring replacement.
  • J
    Jennifer WigginsAug 26, 2025
    What causes MULTIQUIP Vibratory rammers & tampers to be hard to start with normal compression?
    • M
      Melissa BeckerAug 26, 2025
      If your MULTIQUIP Vibratory rammers & tampers is difficult to start, but has fuel, spark, and normal compression, the issue might be due to the wrong fuel type. To resolve this, flush the fuel system and replace it with the correct type of fuel. Water or dust in the fuel system can also cause this, so flush the fuel system. A dirty air cleaner can be the culprit; clean or replace it. Also, ensure the choke is closed.
  • J
    James HowardAug 27, 2025
    Why MULTIQUIP MTX60HD Vibratory rammers & tampers is difficult to start with spark?
    • S
      sotowilliamAug 27, 2025
      If your MULTIQUIP Vibratory rammers & tampers is difficult to start, but fuel is available and there is a spark, the ON/OFF switch might be shorted. Check the switch wiring and replace the switch if necessary. The ignition coil could be defective, so replace it. The spark gap might be improper, or the points might be dirty; set the correct spark gap and clean the points. The condenser insulation could be worn or short circuiting, so replace the condenser. Finally, the spark plug wire could be broken or short circuiting, requiring replacement of the defective spark plug wiring.
  • S
    smithkennethAug 29, 2025
    What to do if MULTIQUIP MTX60HD runs but doesn't jump?
    • A
      Angela MillerAug 30, 2025
      If your MULTIQUIP Vibratory rammers & tampers engine runs but the rammer jumps erratically or not at all, the throttle lever operating speed might be set incorrectly; set it to the correct position. If there's excess oil, drain it to the correct level. A slipping clutch can cause this; replace or adjust the clutch. Spring failure can also be a cause; replace the spiral spring. Ensure the engine speed is correct by adjusting it to the proper operating RPM setting. Finally, over-compacted soil can prevent proper jumping; shut down the machine and test the soil.
  • B
    Brian KellyAug 31, 2025
    Why is there no fuel at the carburetor of my MULTIQUIP MTX60HD?
    • T
      thomaskellieSep 1, 2025
      If your MULTIQUIP Vibratory rammers & tampers has no fuel present at the carburetor, it could be due to several reasons. The fuel tank might be empty, so fill it with the correct type of fuel. The fuel cock might not be opening properly, so apply lubricant to loosen the fuel cock lever, and replace it if necessary. The fuel filter or lines could be clogged, so replace the fuel filter. The fuel tank cap breather hole might be clogged, so clean or replace the fuel tank cap. Finally, there might be air in the fuel line, so bleed the fuel line.
  • R
    Ronald AllenSep 2, 2025
    Why is my MULTIQUIP MTX60HD Vibratory rammers & tampers weak but not misfiring?
    • J
      Joseph McdonaldSep 3, 2025
      If your MULTIQUIP Vibratory rammers & tampers is weak in power but does not misfire, even with proper compression, the air cleaner might be dirty, so clean or replace it. The carburetor level could be improper, so check the float adjustment and rebuild the carburetor. The spark plug might be defective, so clean or replace it. The spark plug gap could be improper, so set it to the proper gap.
  • H
    hmitchellSep 4, 2025
    What to do if MULTIQUIP MTX60HD Vibratory rammers & tampers won't start with key ON?
    • J
      jgreenSep 4, 2025
      If your MULTIQUIP Vibratory rammers & tampers won't start and there's no power with the key ON, the ON/OFF device might not be activated. Turn on the ON/OFF device. The battery might be disconnected or discharged, so check the cable connections and charge or replace the battery. The ignition switch or wiring might be defective, so replace the ignition switch and check the wiring.
  • J
    jasminegonzalezSep 6, 2025
    Why is the exhaust from my MULTIQUIP MTX60HD Vibratory rammers & tampers black?
    • A
      Anthony HarrisSep 6, 2025
      If the exhaust color of your MULTIQUIP Vibratory rammers & tampers is continuously black, it could be due to a clogged air cleaner, so clean or replace it. The choke valve might be set to the incorrect position, so adjust it to the correct position. The carburetor might be defective, or the seal on the carburetor might be broken, so replace the carburetor or seal. Also, the carburetor adjustment might be poor, causing the engine to run too rich, so adjust the carburetor.

Summary

Proposition 65 Warning

Parts Ordering Procedures

Safety Information

Safety Messages and Symbols

Explains the meaning of safety messages (DANGER, WARNING, CAUTION, NOTICE) and associated hazard symbols.

General and Rammer Safety

Covers general operating safety, personal protective equipment, and specific rammer handling guidelines.

Engine and Fuel Safety

Details engine exhaust hazards, safe fuel handling, and fire prevention measures.

Transporting and Environmental Safety

Outlines safe practices for moving the equipment and proper disposal of hazardous waste.

Specifications

Rammer and Engine Specifications

Lists physical dimensions, capacities, power output, and operating parameters for the rammer and engine.

Noise and Vibration Emissions Data

Provides measured sound power/pressure levels and hand-arm vibration data according to specific directives.

General Information

Components Overview

Basic Engine Information

Inspection Procedures

Oil Bath and Engine Oil Checks

Guides on checking oil levels and grades for the rammer's oil bath and engine lubrication.

General Equipment Inspection

Covers pre-operation checks like fasteners, cleaning, and decal condition.

Operation Guidelines

Initial Engine Startup Sequence

Step-by-step instructions for starting the rammer engine, including choke and purge bulb usage.

Rammer Operation and Stopping

Details engaging tamping action, operating at speed, and safe engine shutdown procedures.

Maintenance Schedule

Daily and Periodic Maintenance Tasks

Outlines routine checks and cleaning based on operating hours and time intervals.

Long Term Storage Preparation

Procedures for preparing the equipment for extended periods of non-use, including draining fuel and protecting components.

Troubleshooting Engine and Rammer Issues

Engine Starting and Running Problems

Diagnoses and solutions for common engine issues such as no spark, fuel problems, or overheating.

Rammer Operational Faults

Addresses issues like erratic jumping or lack of rammer action, and potential causes like incorrect speed or clutch slip.

Explanation of Code in Remarks Column

Suggested Spare Parts List

Nameplates and Decals

Crankcase and Engine Assembly Details

Crankcase and Engine Component Diagrams

Illustrated breakdown of the crankcase and engine assembly parts with numbered references.

Crankcase and Engine Parts Listing

Detailed part numbers and descriptions for the crankcase and engine assembly components.

Guide Cylinder Assembly

Foot Assembly Details

Foot Assembly Component Diagram

Visual representation of the rammer's foot assembly parts with numbered labels.

Foot Assembly Parts List

Catalog of specific part numbers and quantities for the foot assembly.

Fuel Tank and Handle Assembly

Fuel Tank and Handle Component Diagram

Illustrated breakdown of the fuel tank and handle assembly components with numbered references.

Fuel Tank and Handle Parts List

List of specific part numbers and quantities for the fuel tank and handle assembly.

Combination Lever Assembly

Tools and Fixtures

Honda GX100 UKRBF Engine Assemblies

Cylinder Barrel Assembly

Illustrated parts breakdown for the engine's cylinder barrel and associated components.

Crankcase Cover Assembly

Exploded view and parts list for the engine's crankcase cover.

Crankshaft Assembly

Diagram and part numbers for the engine's crankshaft and bearing.

Piston and Connecting Rod Assembly

Illustrated parts for the engine's piston, rings, pin, and connecting rod.

Camshaft Assembly

Breakdown of the engine's camshaft, valves, springs, and related parts.

Recoil Starter Assembly

Components of the engine's recoil starter mechanism, including rope and knob.

Fan Cover Assembly

Diagram and parts list for the engine's cooling fan cover.

Carburetor Assembly

Illustrated parts for the engine's carburetor, noting serial number variations.

Air Cleaner Assembly

Diagram and part list for the engine's air cleaner system.

Muffler Assembly

Illustrated parts and breakdown of the engine's muffler and protector.

Flywheel Ignition Assembly

Components of the engine's flywheel, ignition coil, and starter pulley.

Control Assembly

Illustrated parts for the engine's control mechanisms, such as the governor assembly.

Labels Assembly

Identification of various labels and decals applied to the engine.

Terms and Conditions of Sale

How to Get Help

MULTIQUIP MTX60HD Specifications

General IconGeneral
BrandMULTIQUIP
ModelMTX60HD
CategoryVibratory rammers & tampers
LanguageEnglish