Figure 6: Vent Machine Wiring
Notes:
During normal operation, the RBU-27 SE connects L1 through PWR to the Platinum relays. During emergencies, the
RBU stops supplying power to the Platinum controller.
The RBU-27 SE can only open the vent machines.
If the vent machines operate backwards, swap the L1 and L2 wires at the Platinum relays or at the vent machine.
Do not change the wiring on the vent machine left terminal.