9270-20-00 51 noitceS
- 11-11-20 9 -
Specifications
Crankcase Balance Vent Connection: 1/2 NPTF (top).
Inlet Connection: 2 x 3/4 NPTF (side)
1 x 3/4 NPTF (bottom)
Thumb-Valve
TM
Material: Viton
Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC
Wire leads: 18 AWGT x 14 in +/- 2 in (355 mm) length.
Conduit Connection: 1/2 inch conduit (female, top). (Refer to 00-02-0735 Teflon Tape Wrapping Technique).
Case: Die cast aluminum
Lens: Clear “Frog Eye” non-staining, high impact, high temperature nylon; UV and heat stabilized.
Dial: High visibility white background with solid green band for normal level indication.
Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure).
Maximum Differential: 2 in (51mm) between running and stopped.
Maximum Ambient Temperature: 250
o
F (121
o
C)
Float: 3
04 Stainless Steel
Flow Rates: Refer to Flow Rate Chart on page 3
.
M
ur
C
al
c
CALL MURCAL TO PLACE YOUR ORDER
P:(661)272-4700 F:(661)947-7570
www.murcal.com
e-mail: sales@murcal.com